AAMA Test Reports

When you buy super-insulating fiberglass SeriousWindows, you can rest assured in knowing that you are getting high performance windows that meet the standards of AAMA (the American Architectural Manufacturers Association). AAMA, a third-party organization that is a leading window industry source of performance standards and certification, rates the window's ability to withstand wind loads, water resistance and air infiltration rate.

Air Infiltration: Critical to the Energy Performance of Your Windows

When understanding the benefits of super-insulating SeriousWindows, it is important to understand the amount of heating or cooling that can leak around the window, or "infiltrate". The air infiltration rate measures the amount of air that passes through a window. The lower the air infiltration rate, the lower amount of air passes through gaps in or around the window. In other words, the less heating and cooling is leaking out of your window frames. Air infiltration is typically measured in CFM/ft² (cubic feet of air per minute/square footage of the window). The Efficient Windows Collaborative recommends selecting windows that have an air infiltration rate of 0.3 or below. Many styles of super-insulating SeriousWindows have an air infiltration value of less than 0.05. SeriousWindows keeps your heating and cooling inside, helping to reduce your energy bills and provide you with more consistent, year-round comfort.

AAMA Test Report Summaries: SeriousWindows Series 525, 725, 925, 1125 (Single hung, double hung, and horizontal slider styles are available only in Series 525 and 725).

Window Style AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 ANSI/AAMA/NWWDA 101/I.S.2-97 Forced Entry Resistance Operating Force - top/right N (lbf) Operating Force - bottom/left N (lbf) maintaining Air Infiltration @75 Pa or 1.57 psf L/s/m2 (cfm/ft2 ) Water Penetration Resistance Test Pressure Pa (psf) Uniform Load Structural Test Pressure Pa (psf)
Single Hung CW-PG30
(55" x 91")
C-30
(55" x 91")
C-30
(55" x 91")
ASTM F-588 Grade 20   156 (35) .36 (0.07) 330 (6.89) 2160 (45.11)
Double Hung LC-PG25
(55" x 91")
LC-25
(55" x 91")
LC-25
(55" x 91")
ASTM F-588 Grade 10   169 (38) .81 (0.16) 360 (7.52) 1800 (37.59)
Horizontal Slider R-PG100
(63" x 43")
R-100
(63" x 43")
R-100
(63" x 43")
ASTM F-588 Grade 30 33.36 (7.5)   0.33 (0.07) 720 (15) 7200 (150.4)
Casement Window CW-PG45
(31" x 59")
C-45
(31" x 59")
C-45
(31" x 59")
ASTM F-588 Grade 40   4 (1.0) <0.05 (<0.01) 360 (7.52) 3240 (67.67)
Awning Window CW-PG40
( 48 x 31)
C-40
( 48" x 31 ")
C-40
( 48" x 31 ")
ASTM F-588 Grade 10   12 (2.8) .30 (.05) 580 (12.11) 2880 (60.15)
Picture Window
(high profile)
CW-PG45
(60" x 60")
C-45
(60" x 60")
C-45
(60" x 60")
ASTM F-588     < 0.05 (< 0.01) 580 (12.11) 3240 (67.67)
Picture Window
(low profile)
CW-PG50
(60" x 60")
C-50
(60" x 60")
C-50
(60" x 60")
ASTM F-588     < 0.05 (< 0.01) 580 (12.11) 3600 (75.19)